YEAR BUILT / SQUARE FOOTAGE
2000
± 10% 0ffice area (with call center and
multiple restroom locations
Free-standing building
CLEAR HEIGHT
22’ ceiling height
TYPICAL COLUMN SPACING
40’ W x 40’ D
STRUCTURE
Tilt-up, steel framing
Concrete slab
ROOF
New roof in 2013
GENERATORS
Two (2) 2,000 KW diesel generators in
enclosures
Two (2) 500 K V A UPS systems
WATER SERVICE / SIZE
Waste management area enclosure
HVAC CAPACITY
100% HVAC
(3) Cooling towers and chillers
FIRE SPRINKLERS
Fully-sprinklered (Class III Commodity)
ELECTRICAL SERVICE
3000 amps
480 Volt, 3-phase
LIGHTING
LED Warehouse/Production Room Lighting
ZONING
City of Coppell – Light Industrial
PARKING
Ample surface parking (213) (Expandable to
269)
LOADING
Ten (10) total dock doors (4 with levelers,
dock shelters, and dock locks)
Three (3) in an enclosure
1 semi-dock ramp, 1 concrete ramp